DSX2-5000 AP
Key features
Accelerates every step of the copper certification process
- Versiv™ modular design supports copper certification, fiber optic loss, OTDR testing and fiber end-face inspection
- Unmatched speed for Cat 6A, 8, Class FA, I/II and all current standards
- ProjX™ system manages job requirements and progress from set-up to systems acceptance, making sure all tests are completed correctly
- Taptive™ user interface simplifies set-up, and eliminates errors
- Analyze test results and create professional test reports using LinkWare™ management software View More >
The DSX CableAnalyzer Series copper cable certifiers nbsp;enables testing and certification of twisted pair cabling for up to 40 Gigabit Ethernet deployments and will handle any cabling system whether it is a Cat 5e, 6, 6A, 8 or Class FA and I/II. Certifying a cable is one part of a process that starts with system design and ends with system acceptance. The faster that process goes, the more profitable you’ll be. Unfortunately, there are a lot of things that slow the process down – setting up the tester incorrectly, testing to the wrong limits, waiting for skilled technicians to analyze and troubleshoot failures, misinterpretation of results, and producing test reports that customers cannot understand.
As part of the Versiv cabling certification product family, the DSX CableAnalyzer Series copper cable certifiers provides accurate, error-free certification. In the installation business there are multiple teams, varying media types and multiple testing requirements. The difference between being profitable or not is just a few percentage points. The DSX certifies copper cabling, complies with all standards including Level VI/2G accuracy, making jobs easier to manage, and getting to system acceptance faster. It’s not just for the expert technicians and Project Managers. Individuals of various skill levels can improve the set-up, operation, test reporting, and simultaneously manage diverse projects.
Features:
Unique Features:
Versiv enables users to accomplish more than ever before with a cable tester, by accelerating every step of the testing process
LinkWare Live cloud service lets the Project Manager remotely set up the testers, monitor job progress and even location from any smart device
ProjX™ management system eases tasks from initial set-up of a job to system acceptance. It eliminates redundant steps, and ensures that all tests are completed correctly the first time, and every time
Taptive™ user interface puts advanced data analysis and easy set-up and operation at the fingertips of technicians of all skill levels
LinkWare PC management software provides unmatched analysis of test results and professional test reports
The DSX reduces the time required to fix cabling faults with dedicated diagnostics, a simple test that locates the problem
Standards:
Compliant with ANSI/TIA-1152-A Level 2G and proposed standard IEC 61935-1 Ed. 5 Level VI field tester accuracy requirements to 2000 MHz
Supports the complete suite of Resistance Unbalance standards needed for Power over Ethernet (PoE) –IEEE 802.3bt, ANSI/TIA/EIA-568, ISO/IEC 11801 series documents
TCL and ELTCTL measurements compliant to IEC 61935-1-1 (Draft)
Screen continuity along path of cabling
Performance:
Eight second Cat 6A test time contributes to the fastest way to gain certification Graphically displays the source of failures including crosstalk and distance to shield faults for faster troubleshooting Manage up to 12,000 Cat 6A test results with full graphics Capacitive touchscreen allows quick tester setup with easily selectable cable types, standards and testing parameters Integrated Wi-Fi allows you to easily upload results to LinkWareTM Live Over 1 billion links reported on LinkWare PC management software
Manage up to 12,000 Cat 6A test results with full graphics
Managing the testing of multiple jobs with multiple teams, testers, and requirements is time consuming and a source of errors. Increasingly larger jobs make project organization more important than ever. The new ProjX management system on the DSX CableAnalyzer Series copper cable certifiers provides individual project files for all job specific details to be saved under a simple name, eliminating the need to re-enter job specific details after starting a project. This minimizes set-up errors or lost files when switching from one job to another or utilizing multiple testers on a single job. In addition, it provides test results by cable ID, merges any changes without duplicates and defaults to the last copper or fiber module installed. ProjX management system provides real time status to completion on each job with a 0-100% scale and gives the operator the option to isolate any test requiring a second look and helps to assure nothing is overlooked. The "Fix Later" selection creates a punch list or automatic to do list for correcting any workmanship issues. ProjX enables project managers and crew leaders to be truly efficient.
Capacitive touchscreen allows quick tester setup and supports all standards
Taptive user interface is easy enough for even the newest technician to perform tests across multiple media types and testing requirements. The capacitive Taptive user interface makes all jobs easily accessible from the menu screen. Touch the job you’re working on and the large display confirms the test that needs to be performed, animated instructions simplify setting the configuration making correct testing assured.
LinkWare™ PC Cable Test Management Software
Leveraging the popular and multi-featured LinkWare PC management software application, DSX CableAnalyzer Series users can easily access the ProjX management system data, generate reports, and upgrade the software in their testers. Project Managers have full capabilities to manage workflow and consolidate test results. Users can provide the finishing touch by adding their company logo to the report and offer it unaltered to their customers for system acceptance purposes. Keep your business tools simple, no matter which Fluke Networks copper or fiber tester you are using, LinkWare PC is the software package that reports it all.
Now with LinkWare PC stats, the new automated statistical report option, you can move above and beyond the page-per-link report and see your entire cabling infrastructure. It analyzes and transforms LinkWare PC test results data into charts and diagrams that reveal your cabling plant performance; this report summarizes your entire cabling infrastructure in a compact, graphical format that makes it easy to verify margins and to spot anomalies.
LinkWare™ Live Test Results Management Service
LinkWare Live is a cloud-based service that lets you manage certification jobs anytime, anywhere, with anyone on any device. With LinkWare Live, you can Keep track of every test on every job. Get an overview of every project from any smart device. Drill down to each individual test. Instantly receive notification of incorrect test setting or cable IDs. Get it right the first time. Define cable IDs and test settings from your PC or tablet. Then send them to the testers or Brother printers at the jobsite for mistake-free testing and labeling. Keep your testers up to date. Standards can change without notice, and an out-of-date test report can mean hours of re-testing. LinkWare Live automatically ensures your testers are running the latest. Stop wasting time and gas driving testers back to the office. Integrated Wi-Fi allows you to upload your test results straight from the job site to LinkWare Live. Then download them automatically to the right job for fast report generation with LinkWare PC. Avoid Project Delays. Track the last used location and monitor the status of all testers to ensure they are always calibrated and running the latest firmware* Supports all Versiv models: DSX CableAnalyzer Series, CertiFiber Pro, OptiFiber Pro, and the FI-7000.
Electrically centered plug design is compliant with TIA Level 2G and IEC Level VI accuracy requirements to 2000 MHz with a future-ready design to support all hardware upgrades
The DSX CableAnalyzer Series enables cable testing and certification for network deployments up to 40 Gigabit Ethernet – whether it is an existing Cat 5e, 6, 6A, 8 or Class I/II cabling system, the DSX tests to all industry standards. The electrically centered test plug results in the Level 2G/VI accuracy required to support field testing to Cat 8 / Class I/II, 2000 MHz. The DSX exceeds the IEC Level VI and TIA Level 2G specifications assuring you of higher confidence in results over the full frequency range. Higher performance cabling systems like Cat 8 require more precise measurement to ensure they are providing the noise immunity required by 25G and 40G applications. Additionally, complex Alien Crosstalk link-to-link certification is simplified by integrating the measurement capability into each copper module up to 40GBASE-T testing. The DSX is the first field tester to support balance measurements including Transverse Conversion Loss (TCL) and Equal Level Transverse Conversion Transfer Loss (ELTCTL). TCL and ELTCTL are important measurements found in the cabling standards. They define a minimum performance for balance, a key parameter to help determine noise immunity. Industrial network owners/operators are especially interested in this property due to the higher level of electromagnetic interference (EMI) within the industrial environment. Fluke Networks' DSX CableAnalyzer Series has obtained Intertek (ETL) verification in accordance with the ANSI/TIA-1152-A specification for Level 2G test equipment. (Report on file.)
Eight second Cat 6A test time and the fastest way to submit your certification results
No tester offers so much speed for so many tests. Complete copper certification to Cat 6A in 8 seconds or certify two fibers at two wavelengths in just 3 seconds. Endorsements by cabling vendors worldwide assure that Versiv is the fastest way to project completion and system acceptance. Quickly get a Pass or Fail result and easily review individual test parameters by value or drill into specific area on a graph.
Graphically displays the source of failures including crosstalk and distance to shield faults for faster troubleshooting
The DSX reduces the time required to fix cabling faults with dedicated diagnostics, a simple 1 button test runs all tests and saves all data. The graphical results screen allows you to look down the cable to see exactly where any cross talk, return loss or shield faults are located on any given link. Previous testers had frequency limits of their diagnostic capabilities of up to 250 MHz only, but the DSX CableAnalyzer Series removes this limitation. This common view is easily interpreted by novice and expert users alike to isolate and act on any failed results quickly and is stored with the test result for remote analysis.
Comparing the DSX-8000 and DSX-5000
The DSX CableAnalyzer Series family copper cable certifier is based on two modules: the DSX-5000 and DSX-8000. The DSX-5000 certifies twisted pair Cat 5e, 6, 6A and Class FA cabling with limits up to 1000 MHz. The DSX-8000 certifies twisted pair Cat 5e, 6, 6A, 8 and Class I/II cabling with limits up to 2000 MHz.
Copper Certification | ||
DSX-8000 CableAnalyzer™ | DSX-5000 CableAnalyzer™ | |
Category 6A / Class EA test time | 8 seconds | 10 seconds |
Category 8 / Class I/II test time | 15 seconds | |
HDTDX/HDTDR diagnostic test times | ≈ 3 seconds | ≈ 3 seconds |
Internal memory |
≈ 5,000 Cat 8 with plots ≈ 12,000 Cat 6A with plots |
≈ 12,000 Cat 6A with plots |
Level V Accuracy (1 GHz) | ✓ | ✓ |
Level VI/2G Accuracy (2 GHz) | ✓ | |
Resistance Unbalance measurement | ✓ | ✓ |
Shield integrity check | ✓ | ✓ |
TCL measurement | ✓ | ✓ |
ELTCTL measurement | ✓ | ✓ |
CDNEXT measurement | ✓ | ✓ |
CMRL measurement | ✓ | ✓ |
Built in Alien XTalk module | ✓ | ✓ |
Channel Adapter | 2 GHz Range | 1 GHz Range |
Permanent Link Adapter | 2 GHz Range | 1 GHz Range |
Optional Accessories | ||
Patch cord adapters | Category 5e, 6 and 6A patch cord | Category 5e, 6 and 6A patch cord |
Coax Adapter | ✓ | ✓ |
M12 Adapter | ✓ | ✓ |
TERA Adapter | ✓ | ✓ |
GG45 Adapter | ✓ | ✓ |
MPTL Certification
There may be scenarios where a typical four-connector channel is not used when connecting these types of devices– especially those that reside in the ceiling space where it is impractical to install a faceplate. Instead, there is just one patch cord in the telecommunications room and the permanent link is terminated at the other end with a plug so it can plug directly into the device, essentially eliminating the equipment cord. This creates what is now known as a Modular Plug Terminated Link, or MPTL.
The DSX CableAnalyzer™ is capable of certifying MPTL by using a patch cord adapter on one end and a permanent link on the opposite end (see image below).
Industrial Ethernet Support
Validate that cables conform to international standards
The DSX2-5-IE-K1 provides complete testing for copper cabling from single pair to Cat 6A, and includes adapters for RJ-45, M12-D and M12-X. Approved by over 30 cabling manufacturers. Startup faster: Ensure cable performance at machine builder, commissioning and after making changes Prevent downtime: Find marginal cables susceptible to vibration, moisture, noise and temperature Speed troubleshooting: Avoid wasting time installing bypass cables. Identify the exact type and location of cable failure—or prove it’s good Supports cabling for EtherNet/IP™, PROFINET, ModBus TCP™ and other protocols. Supports RJ45 and M12 connectors
Support for M12 and ix Industrial® Connectors
The DSX Series offers adapters for industrial connectors, including M12D code (2 pair) M12X code (4 pair) – Endorsed by Panduit Ix Industrial® - Test Adapters available from HARTING and HIROSE
Specifications:
Cable Types | |
Shielded and unshielded pair LAN cabling | TIA Category 3, 4, 5, 5e, 6, 6A, 8: 100 Ω ISO/IEC Class C, D, E, EA, F, FA and I/II: 100 Ω and 120 Ω |
Standard Link Interface Adapters | |
Permanent link adapters | Plug type: shielded RJ45 Optional Plug type: Tera |
Channel Adapters | Jack type: shielded RJ45 Optional Jack type: Tera, GG45 |
Test Standards | |
TIA | Category 3, 4, 5, 5e, 6, 6A, 8 per ANSI/TIA-568.2-D |
ISO/IEC | Class C and D, E, EA, F, FA and I/II certification per ISO/IEC |
Maximum frequency |
DSX-8000: 2000 MHz; DSX-5000: 1000 MHz |
General Specifications | |
Speed of Autotest | DSX-8000: Full 2-way Autotest of Category 5e or 6/Class D or E: 7 seconds. Full 2-way Autotest of Category 6A/Class EA: 8 seconds. Full 2-way Autotest of Category 8: 16 seconds DSX-5000: Full 2-way Autotest of Category 5e or 6/Class D or E: 9 seconds. Full 2-way Autotest of Category 6A/Class EA: 10 seconds |
Supported test parameters (The selected test standard determines the test parameters and the frequency range of the tests) | Wire Map, Length, Propagation Delay, Delay Skew, DC Loop Resistance, Pair-to-Pair Resistance Unbalance, Pair Resistance Unbalance, Insertion Loss (Attenuation), Return Loss (RL), Common Mode Return loss (CMRL), Near End Crosstalk (NEXT), Far End Crosstalk (FEXT), Attenuation-to-crosstalk Ratio (ACR-N), ACR-F (ELFEXT), Power Sum ACR-F (ELFEXT), Power Sum NEXT, Power Sum ACR-N, Power Sum Alien NEXT (PS ANEXT), Power Sum Alien Attenuation NEXT Ratio Far End (PS AACR-F), Common Mode to Differential Mode NEXT (CDNEXT),Transverse Conversion Loss (TCL), Equal Level Transverse Conversion Transfer Loss (ELTCTL) |
Input protection | Protected against continuous telco voltages and 100 mA over-current. Occasional ISDN over-voltages will not cause damage |
Display | 5.7 in LCD display with a projected capacitance touchscreen |
Case | High impact plastic with shock absorbing overmold |
Dimensions | Main Versiv unit with DSX module and battery installed: 2.625 in x 5.25 in x 11.0 in (6.67 cm x 13.33 cm x 27.94 cm) |
Weight | Main Versiv unit with DSX module and battery installed: 3 lbs, 5oz (1.28 kg) |
Main unit and remote: | Lithium ion battery pack, 7.2 V |
Typical battery life: | 8 hours |
Charge time* | Tester off: 4 hours to charge from 10 % capacity to 90 % capacity. |
Languages supported | English, French, German, Italian, Japanese, Portuguese, Spanish, Chinese, Korean, Russian, Trad Chinese, Czech, Polish, Swedish, Hungarian |
Calibration | Service center calibration period is 1 year |
Integrated Wi-Fi | Meets IEEE 802.11 a/b/g/n; dual band (2.4 GHz and 5 GHz) |
Environmental Specifications | |
Operating Temperature | 32°F to 113°F (0°C to 45°C) |
Storage Temperature | -14°F to +140°F (-10°C to +60°C) |
Operating relative humidity | 0 % to 90 %, 32°F to 95 °F (0°C to 35°C) 0 % to 70 %, 95°F to 113 °F (35°C to 45°C) |
Vibration | Random, 2 g, 5 Hz-500 Hz |
Shock | 1 m drop test with and without module and adapter |
Safety | CSA 22.2 No. 61010, IEC 61010-1 3rd Edition |
Operating altitude | 13,123 ft (4,000 m) 10,500 ft (3,200 m) with ac adapter |
EMC | EN 61326-1 |
Performance Specifications ** | ||
DSX-8000 | Category 8 test modes (or lower link categories) Class I/II test modes | ANSI/TIA-1152 Level 2G Proposed standard IEC 61935-1 Ed. 5 Level VI |
DSX-5000 | Category 6A/Class EA test modes (or lower link categories) Class FA test modes | Exceed Level IIIe requirements of TIA 1152 and Level IV of IEC 61935-1. Exceed Level V requirements as in the draft 4th edition of IEC 61935-1. |
Length of Twisted Pair Cabling1 | ||
Range | 800 m (2600 ft) | 150 m (490 ft) |
Resolution | 0.1 m or 1 ft | 0.1 m or 1 ft |
Accuracy | ± (0.3 m + 2 %); 0 m to 150 m ± (0.3 m + 4 %); 150 m to 800 m |
± (0.3 m + 2 %) |
Propagation Delay | ||
Range | 4000 ns | 750 ns |
Resolution | 1 ns | 1 ns |
Accuracy | ± (2 ns + 2 %); 0 ns to 750 ns ± (2 ns + 4 %); 750 ns to 4000 ns | ± (2 ns + 2 %) |
Delay Skew | |
Range | 0 ns to 100 ns |
Resolution | 1 ns |
Accuracy | ± 10 ns |
DC Loop Resistance Test | |
Range | 0 Ω to 540 Ω |
Resolution | 0.1 Ω |
Accuracy | ± (1 Ω + 1 %) |
Overload recovery time | Less than 10 minutes to rated accuracy following an overvoltage. Referencing is required after repeated or prolonged overvoltage. |
DSX2-5000 Standard Accessories:
DSX-ADD | DSX-5000 Add-on Kit |
DSX2-ADD-R | DSX2-5000 Add-on Kit with Remote (not compatible with original Versiv main) |
DSX2-CFP-Q-ADD-R | DSX2-5000 with Quad OLTS Add-on Kit with Remote (not compatible with original Versiv main) |
DSX-OFP-Q-ADD | DSX-5000 with Quad OTDR Add-on Kit |
DSX-PLA011S | DSX-5000 TERA Cat 7A/Class FA PLA Set |
DSX-CHA011S | DSX-5000 TERA Cat 7A/Class FA CHA Set |
DSX-CHA-5-GG45-S | DSX GG45/ARJ45 Class FA Channel Adapter Set (1 GHz) |
Optional Accessories for DSX Cable Analysers Series:
DSX-PLA004S | DSX Cat 6A/Class EA Permanent Link Adapter Set |
DSX-PLA004-RKIT | Cat 6A/Class EA PLA Adapter – Plug Replacement Kit |
DSX-CHA004S | DSXcCat 6A/Class EA Channel Adapter Set |
DSX-COAX | DSX Coax Adapter Set |
DSX-CHA021S | DSX M12 4-Position Adapter Set |
DSX-PC5ES | DSX Patch Cord Test Adapter Set for Cat 5e patch cords |
DSX-PC6S | DSX Patch Cord Test Adapter Set for Cat 6 patch cords |
DSX-PC6AS | DSX Patch Cord Test Adapter Set for Cat 6A patch cords |
DSX-PC5E | Single Patch Cord Adapter for Testing Cat 5e MPTL |
DSX-PC6 | Single Patch Cord Adapter for Testing Cat 6 MPTL |
DSX-PC6A | Single Patch Cord Adapter for Testing Cat 6A MPTL |
Versiv-TSET | VERSIV Headphones |
VERSIV-BATTERY | VERSIV Battery |
VERSIV-ACUN | VERSIV Charger |
VERSIV-STRP | VERSIV Hand Strap |
VERSIV-STND | VERSIV Demo Stand |
DSX-5000 Gold Support Models:
GLD-DSX-5000 | 1 year Gold Support, DSX2-5000 or DSX-5000 |
GLD3-DSX-5000 | 3 year Gold Support, DSX2-5000 or DSX-5000 |
GLD-DSX-5000QI | 1 year Gold Support, DSX2-5000QI or DSX-5000QI |
GLD3-DSX-5000QI | 3 year Gold Support, DSX2-5000QI or DSX-5000QI |
GLD-DSX-ADD-R | 1 year Gold Support, DSX2-5000-ADD-R or DSX-ADD-R |
GLD3-DSX-ADD-R | 3 year Gold Support, DSX2-5000-ADD-R or DSX-ADD-R |
GLD-DSX-CFP-Q-ADDR | 1 year Gold Support, DSX2-CFP-Q-ADD/R or DSX-CFP-Q-ADD-R |
GLD3-DSX-CFP-Q-ADD | 3 year Gold Support, DSX2-CFP-Q-ADD/R or DSX-CFP-Q-ADD-R |
The information below is required for social login
Sign In
Create New Account